Take Control of Your AC Test Power
The ASX Series is a family of High Performance Switching AC power sources
covering the power range from 1.5kVA to 6kVA (12kVA to be released soon). The
product line offers both single and three phase models. Units are
conservatively designed and output power ratings are based on the most severe
combination of input line, output voltage, power factor, and temperature.
Great emphasis has been placed on low acoustic noise, ease of installation, and
maximum power per cubic inch of rack space. Control and operational features
provide a high degree of application versatility and ease of use for the test
engineer. Applications range from simple, manually controlled frequency
conversion to harmonic testing and sophisticated bus programmable transient
simulation.
Power conversion within the ASX Series is achieved by high frequency pulse width
modulation, resulting in cool, quiet and efficient operation.
Key Features Provide Application Versatility
-
22 Waveform Library - Arbitrary Waveform Generator
-
15 to 1,200 Hz Operation - 5,000 Hz Bandwidth
-
Precision True-RMS metering of volts, amps, and power for displays and
reporting
- Now compatible with UPC Studio graphical user interface
-
RS-232 Interface with SCPI compatibility
-
1 Phase/3 Phase Switch Selectable Output from front panel or bus command
-
99 stored programs for both static and dynamic Transient Testing
-
LabVIEW for Windows®/LabWindows® drivers
-
Waveform Creation by Harmonic Synthesis
|
 |
-
Harmonic Analysis (Voltage and Current)
-
Metering of RMS and Peak Values
-
Continuous Self Calibration (CSC)
-
Precision Voltage Programming - 0.05% with CSC engaged
-
Programmable Output Impedance
-
Up to 0-300 VAC Direct Coupled Out
-
Power Levels from 1.5 kVA to 12 kVA
-
Externally Referenced Meter Calibration
-
CE and ETL Mark available
-
Design Provides Total Control of AC Power
|
Design Provides Total Control of AC Power
-
All ASX Series power source models may be equipped with a digitally programmable
Oscillator/Controller or a manual version.
-
Single phase power source models may be controlled to operate on either a 0-135
VAC range or a 0-270 VAC range. Three phase models are additionally switchable
3ø to 1ø output power form.
-
Total control of the output power form and the selection of either the direct
output or the optional transformer output is available from the front panel or
the bus.
-
All operating functions may be controlled from either the front panel or from a
remote RS-232 or IEEE 488.2/ SCPI BUS. LabVIEW for Windows® and LabWindows®
Instrument Drivers are available.
Special ASX Series Operating Features
Continuous Self Calibration
Provides for exceptional accuracy of the AC output Voltage. When enabled,
accuracy improves to ±0.1% referenced to the power source internal voltmeter.
Programmable Dynamic Output Impedance - Prog-Z (optional on UPC1/3)
Programmable Output Impedance provides the operator with the ability to
dynamically control the output impedance of the AC Power Source. Using the
output current term as conditioned feedback signal to the output voltage
circuits, positive or negative impedance may be programmed. This control
simulates the effects of, or compensates for high peak current, distribution,
or transformer losses of up to ±10% of the output voltage.
This feature creates positive, negative, or zero output impedance (Zo).
Waveform Library
Up to 22 different waveforms can be stored in the waveform library for
execution as part of a steady state program or for substitution in any output
phase as part of a transient test program. Memory location #1 is a non-editable
high resolution sine wave. Locations 2-22 are editable and can be substituted
in any output phase. An unlimited number of waveforms may be stored on the
computer for those using a programmable UPC.
Waveform Edit
A full-featured editor permits modification of a stored waveform in both time
and frequency domains. This method can be used to quickly create spikes,
dropouts, notches and other sub-cycle wave conditions. The resulting modified
waveform is stored for execution in steady-state or transient programs.
Waveform Analysis (optional on UPC1/3)
Provides both graphic (using LabView for WindowsT) and numeric displays of the
harmonic structure of a voltage or current waveform. Each waveform is analyzed
for its harmonic content up to the 51st harmonic. Amplitude and phase are
reported to the local display. The LabVIEWT instrument driver displays numeric
values as well as a graphic summary of the harmonic spectrum.
Waveform Synthesis (optional on UPC1/3)
Quickly create virtually any AC test waveform by building it out of harmonics.
The process is as simple as keying in the magnitude and phase angle of each
desired harmonic up through the 51st. Additionally, waveforms can be created by
downloading from a host PC.
Time Based Transients
Create and execute transients that occur over a specified time segment to
modify the output waveform, voltage, and frequency for any or all phases. An
output trigger is provided for synchronizing external test equipment to the
actual transient event.
Cycle Based Transients
Create and execute transients that substitute a waveform in any or all phases
for 1 to 100 cycles. The waveform being substituted can be selected and/or
modified from the waveform library.
ASX Series AC Power Sources
MODEL
|
RATED
POWER
(VA)
|
OUTPUT
FORM
NOTE 1
|
OUTPUT
VOLTS-
MAX
(Vrms)
NOTE 2
|
OUTPUT
AMPS
(Arms)
|
OUTPUT
AMPS
(Apeak)
NOTE 3
|
INPUT POWER FORM
NOTE 4
|
PANEL HEIGHT (U)
|
WEIGHT (LBS./KG.)
|
115ASX
|
1500
|
1Ø
|
132
|
16
|
35
|
1Ø
|
3
|
65/30
|
120ASX
|
2000
|
1Ø
|
150/300
|
20/14
|
90/45
|
1Ø
|
3
|
75/34
|
140ASX
|
4000
|
1Ø
|
135/270
|
32/16
|
90/45
|
3Ø*
|
5
|
120/55
|
315ASX
|
1500
|
1Ø
3Ø
|
132/264
132 (Vl-N)
|
12/6
4 per Ø
|
69/23
23 per Ø
|
1Ø
|
3
|
60/27
|
320ASX
|
2000
|
1Ø
3Ø
|
135/270
135 (Vl-N)
|
20/12
7 per Ø
|
69/23
23 per Ø
|
1Ø
|
3
|
85/37
|
345ASX
|
4500
|
1Ø
3Ø
|
135/270
135 (Vl-N)
|
36/12
12 per Ø
|
100/40
40 per Ø
|
3Ø*
|
5
|
170/77
|
360ASX
|
6000
|
1Ø
3Ø
|
135/270
135 (Vl-N)
|
48/16
16 per Ø
|
210/70
70 per Ø
|
3Ø*
|
5
|
180/82
|
3120ASX
|
12000
|
1Ø
3Ø
|
135/270
135 (Vl-N)
|
96/32
32 per Ø
|
300/100
100 per Ø
|
3Ø
|
9
|
340/154
|
Notes:
-
All single phase output units (Model 115 ASX excepted) are operable with dual
voltage ranges as listed. Three phase units are operable as single phase with
dual voltage range capability or as three phase. Output voltage ranges and
1ø/3ø conversions are selected by front panel or bus commands.
-
Output voltage ranges listed are for standard units. VMAX is output voltage with
nominal input and full rated load applied. Other voltage ranges are available
with the output magnetics options below.
-
Peak Repetitive Pulse Current.
-
Single phase input: 100, 110, 120, 208, 220 and 240 VAC ±10%. Three phase input:
208,220,240,380,416 and 480 VAC ± 10%. (480 V input and 400 Hz input are each
available as a cost option.) *Single phase version available for added cost.
Applications
AC Test Power
The ASX Series Power Source is equipped with a powerful microcontroller to
create a fully integrated test system. It supplies a variety of power
conditions to the device under test and meters/analyzes all output performance
parameters.
Frequency/Voltage Conversion
The ASX Series is an excellent source of stable AC voltage over the frequency
range of 15 to 1,200 Hz. The output frequency is quartz-crystal stabilized.
Output voltages up to 600 VAC are provided.
Phase Conversion
With the ability to provide singe and three-phase outputs, the ASX Series is
the perfect choice to provide 1 Phase to 3 Phase or 3 Phase to 1 Phase
conversion.
Controller Selection Guide
Six controller models are available with the ASX-Series. They include 1 Phase
and 3 Phase models for both manual and programmable control.
-
UPC-1M, 1 Phase Manual Control, 15 Hz to 1,200 Hz.
-
UPC-3M, 3 Phase Manual Control, 15 Hz to 1,200 Hz.
-
UPC-3EM, 3 Phase Manual Control, 15 Hz to 599 Hz.
-
UPC-1, 1 Phase Programmable Control, 15 Hz to 1,200 Hz.
-
UPC-3, 3 Phase Programmable Control, 15 Hz to 1,200 Hz.
-
UPC-3E, 3 Phase Programmable Control, 15 Hz to 599 Hz.
All controllers provide manual operation from the front panel. Programmable
Controllers may be programmed from the front panel or from a remote interface.
RS232 Interface is standard. IEEE 488 interface is optional.
Power Source Specifications
Output Frequency:
15 to 1,200 Hz. Full Power
Line Regulation:
0.1% max for a ±10% line change.
Load Regulation:
0.25% 15 to 400 Hz., 0.50% 400 to 1,200 Hz. With external sense enabled.
Improves to less than 0.1% with external sense and CSC enabled.
Output Distortion:
0.25% THD 15 to 200 Hz., 0.50% THD 200 to 1,200 Hz.
Ripple and Noise:
-66 dB
Response Time:
60 microseconds typical, 10-90% load step.
Mechanical Specifications
All models are designed for operation in 19 inch equipment racks. Models 4 kVA
and higher have side handles for ease of handling.
Mounting:
Standard 19 inch rack. Slide rails are available as an option for all models.
Height:
See model table above for panel height.
Depth:
Approximately 24 inch, from the front panel to the rear of the chassis.
Cooling:
Front or side forced air intake with rear exhaust. Automatic Fan Speed Control
for low acoustic noise and extended fan life.
Dual Range Output Magnetics Options
ASX Series Power Sources can be equipped with output transformers to provide an
alternate output voltage range. Selection of direct or transformer coupled
range is performed by the controller via front panel or bus command. The
standard frequency range for transformer coupled outputs is 45 to 1,200 Hz.
Standard output ratios are 1.5:1, 2.0:1, and 2.5:1. Transformer outputs are
supplied internally or externally via a Magnetics Module as listed in the above
table. Consult the factory for additional information regarding special output
ranges not listed above.
UPC Series Controller Specifications
The latest additions to Pacific’s SmartsourceT family of UPC Controllers are
the UPC-1M, UPC-3M, UPC-1 and UPC-3. The UPC Controller is a modular component
of the ASX Series and is available in four configurations ranging from 1 Phase
to 3 Phase and Manual Control to Programmable Control. The table below lists
each model according to key features.
All UPC Controllers include precise metering functions with data displayed via
a 160 character LCD display. This, along with the 30-key front panel, provides
the industry’s most powerful and user-friendly controller.
The UPC-1 and UPC-3 controllers are available with either the RS-232 or GPIB
remote interface. Commands are structured in accordance with SCPI (Standard
Commands for Programmable Instruments). The RS-232 serial port operates up to
38.4 Bps. The GPIB interface is compatible with the IEEE-488.2.
Frequency:
Range: 15 to 1,200 Hz. Resolution: 4 significant digits, eg. 50.00, 400.0, etc.
Accuracy: ±0.01%, 15 to 1,200 Hz
Voltage:
Range: 0 to Vmax in 0.1 VAC steps. Accuracy: Executive voltage is within ±50
mVAC (0.05%) of command voltage referenced to the internal voltmeter with CSC
engaged.
Phase Angle:
Phase Separation of Phases B and C are programmable 0 to 360° relative to phase
A on the UPC-3 controller. Phase separation is fixed at 120° and 240°,
respectively, on the UPC-3M controller.
Programmable Current Limit:
Programmable Current limit is provided on the UPC-1 and the UPC-3 controllers.
Programmable range is from 0 to Ipeak, max of the power source.
Output Voltmeter:
The Output Voltmeter is true RMS reading and each phase is measured
independently. Line to neutral and line to line voltages are displayed. Range:
0-354 VACL-N, 0-708 VACL-L. Resolution: 0.1 VAC to front panel, 0.001 VAC to
remote interface. Accuracy: ±0.2% of range + cal. ref.
Output Ammeter:
Output Ammeter is true RMS reading and each phase is measured independently.
RMS and peak currents along with Crest factor are displayed. Range: 300% of
system current rating. Resolution: 0.01 AAC to front panel, 0.001 AAC to remote
interface. Accuracy: ±0.2% of range + cal ref.
Power:
Measures True Power (kW), Apparent Power (kVA) and power factor. Range: Based
on ammeter. Resolution: 1.0 watts or VA to front panel, 1.0 watts or VA to
remote interface.
Power Factor:
Calculated and displayed to three significant digits.
Expanding the AC Power Source into an Automated Test System
Pacific’s line of SmartsourceT AC Power Sources enable the engineer to easily
automate his testing by using Lab VIEW for WindowsT or LabWindowsT. An
extensive list of Virtual Instruments (VIs) are offered for Pacific’s ASX
Series Power Sources.
Call for Technical and Application Assistance
Pacific’s technical people are here to assist you. As a technically oriented
company, we design, manufacture and service leading edge AC Test Power
equipment. We understand your requirement for strong applications support and
we provide it.
Product Brochure and Application Notes
To receive a PDF brochure and/or application notes for this product, please
contact us and check the boxes of the specific product(s) that you are
interested in or login in to the PPS Member area and download the files.
Specifications subject to change without notice.
|