Take Control of Your AC Test Power
The AMX Series is a family of High Performance Linear AC power sources covering
the power range from 500 VA to 12 kVA with standard models and up to 30 kVA
with optional M5283 option. The product line offers both single and three phase
models. Units are conservatively designed and output power ratings are based on
the most severe combination of input line, output voltage, power factor, and
temperature. This approach to product design allows the AMX Series to excel
when delivering the high peak load currents demanded in the AC test
environment.
Great emphasis has been placed on low acoustic noise, ease of installation, and
maximum power per cubic inch of rack space. Control and operating features
provide a high degree of application versatility and ease of use for the test
engineer. Applications range from simple, manually controlled frequency
conversion to harmonic testing and sophisticated bus programmable transient
simulation.
An exceptionally broad bandwidth (50 kHz small signal) combined with peak/RMS
current of 4-6:1 give the AMX Series the ability to produce high quality, low
distortion output power into the most dynamic loads.
Key Features Provide Application Versatility
-
IEEE-488.2 or RS-232C with SCPI compatibility
- Now compatible with UPC Studio graphical user interface
-
LabVIEW for Windows®/LabWindows® drivers
-
Waveform Creation by Harmonic Synthesis
-
Graphical Analysis (Voltage and Current)
-
Harmonic Analysis (Voltage and Current)
-
Metering of RMS and Peak Values
-
Continuous Self Calibration (CSC)
-
Line Sync Option
-
6:1 Peak Current Capability
|
 |
-
Low Impedance for EN61000-3-2, 3 Testing
-
Programmable Output Impedance
-
Up to 0-300 VAC Direct Coupled Out
-
1 Phase / 3 Phase Switch Selectable
-
20-5000 Hz Full Power Bandwidth
-
Power Levels from 500 VA to 12 kVA standard; 30kVA optional
-
Externally Referenced Meter Calibration
-
CE and ETL Mark available
|
Design Provides Total Control of AC Power
-
All AMX Series power source models may be equipped with either a digitally
programmable Oscillator/Controller (UPC type) or a manually controlled
Oscillator (UMC type).
-
Single phase power source models may be controlled to operate on either a 0-135
VAC range or a 0-270 VAC range. Three phase models are additionally switchable
to 3ø/1ø output power form.
-
Total control of the output power form and the selection of either the direct
output or the optional transformer output is available from the front panel or
the bus.
-
All operating functions may be controlled from either the front panel or from a
remote RS-232 or IEEE 488.2/ SCPI BUS. LabVIEW for Windows® and LabWindows®
Instrument Drivers are available.
Special AMX Series Operating Features
Continuous Self Calibration
Provides for exceptional accuracy of the AC output Voltage. When enabled,
accuracy improves to ±0.03% referenced to the power source internal voltmeter.
Programmable Dynamic Output Impedance (optional on UPC12/32)
Programmable Output Impedance provides the operator with dynamic control over
the output impedance of the AC Power Source. Using the output current term as
conditioned feedback signal to the output voltage circuits, positive or
negative impedance may be programmed. The purpose of this control is to
simulate the effects of or compensate for high peak current, distribution, or
transformer losses of up to ±10% of the output voltage.
This feature creates positive, negative, or zero output impedance
(Zo).
-
Compensates for line distribution or transformer losses.
-
Simulates a soft power line for product testing. Compensation range is ±10% of
the output voltage.
Waveform Library
Up to 16 different waveforms can be stored in the waveform library for
execution as part of a steady state program or for substitution in any output
phase as part of a transient test program. Memory location #1 is a non-editable
high resolution sine wave. Locations 2-16 are editable and can be substituted
in any output phase. An unlimited number of waveforms may be stored on the
computer for those using a programmable UPC.
Waveform Edit
Provides the ability to modify a stored waveform by specifying the waveform
amplitude desired at each specific phase angle.
Waveform Analysis (optional on UPC12/32)
Provides both a graphic and numeric display of the harmonic structure of a
voltage or current waveform. Data presented includes the magnitude of each
harmonic in %, the total harmonic distortion, and the odd and even harmonic
distortion in %.
Waveform Synthesis (optional on UPC12/32)
Provides the ability to quickly create virtually any AC Test Waveform that may
be required by building it out of harmonics. The process is as simple as keying
in the harmonic multiple, the amplitude, and the phase angle for each desired
harmonic up through the 51st.
Time Based Transients
Provide the ability to create and execute on command, transients that occur
linearly over a specified time segment to modify output voltage or frequency.
Cycle Based Transients
Provide the ability to create and execute, on command, transients that
substitute a selected waveform in the output for 1 to 100 cycles.
AMX AC Power Sources
MODEL
|
RATED
POWER
(VA)
|
OUTPUT
FORM
NOTE 1
|
OUTPUT
VOLTS-
MAX
(Vrms)
NOTE 2
|
OUTPUT
AMPS
(Arms)
|
OUTPUT
AMPS
(Apeak)
NOTE 3
|
INPUT POWER FORM
NOTE 4
|
PANEL HEIGHT (U)
|
WEIGHT (LBS./KG.)
|
105AMX
|
500
|
1Ø
|
135/270
|
4/2
|
40/20
|
1Ø
|
3
|
60/27
|
108AMX
|
750
|
1Ø
|
135/270
|
6/3
|
40/20
|
1Ø
|
3
|
60/27
|
112AMX
|
1200
|
1Ø
|
150/300
|
10/5
|
40/20
|
1Ø
|
3
|
70/32
|
125AMX
|
2500
|
1Ø
|
150/300
|
20/10
|
90/45
|
3Ø*
|
6
|
110/50
|
140AMX
|
4000
|
1Ø
|
135/270
|
32/16
|
140/70
|
3Ø*
|
8
|
170/77
|
305AMX
|
500
|
1Ø
3Ø
|
135/270
135 (Vl-N)
|
4/2
1.5 per Ø
|
45/15
15 per Ø
|
1Ø
|
3
|
60/27
|
308AMX
|
750
|
1Ø
3Ø
|
135/270
135 (Vl-N)
|
6/2
2 per Ø
|
45/15
15 per Ø
|
1Ø
|
3
|
60/27
|
312AMX
|
1200
|
1Ø
3Ø
|
150/300
150 (Vl-N)
|
10/3.3
3.3 per Ø
|
45/15
15 per Ø
|
1Ø
|
3
|
70/32
|
320AMX
|
2000
|
1Ø
3Ø
|
135/270
135 (Vl-N)
|
18/6
6 per Ø
|
60/20
20 per Ø
|
3Ø
|
5
|
125/57
|
345AMX
|
4500
|
1Ø
3Ø
|
135/270
135 (Vl-N)
|
36/12
12 per Ø
|
165/55
55 per Ø
|
3Ø
|
8
|
170/77
|
360AMX
|
6000
|
1Ø
3Ø
|
135/270
135 (Vl-N)
|
48/16
16 per Ø
|
210/70
70 per Ø
|
3Ø
|
8
|
180/82
|
390AMX
|
9000
|
1Ø
3Ø
|
135/270
135 (Vl-N)
|
72/24
24 per Ø
|
330/110
110 per Ø
|
3Ø
|
16
(2 x 8)
|
340/154
|
3120AMX
|
12000
|
1Ø
3Ø
|
135/270
135 (Vl-N)
|
96/32
32 per Ø
|
420/140
140 per Ø
|
3Ø
|
16
(2 x 8)
|
360/163
|
Notes:
-
All single phase units are operable with dual voltage ranges as listed. All
three phase units are operable as single phase with dual voltage range
capability or as three phase. Output voltage ranges and 1ø / 3ø conversions are
selected by front panel or bus command.
-
Output voltage ranges listed are for standard units. VMAX is achievable with
nominal input voltage at full load. Other voltage ranges are available with the
output magnetics option.
-
Current ratings at 125 VRMS output.
-
Input power frequency is 47-63 Hz (400Hz optional). Single Phase: 100, 110,
120, 200, 208, 220, 230, 240, VAC ± 10%. Three phase: 208, 220, 240, 380, 416
VAC ± 10%. *Single phase version available for added cost.
Applications
AC Test Power
The AMX Series Power Source is equipped with a powerful microcontroller to
create a fully integrated test system. It supplies a variety of power
conditions to the device under test and meters/analyzes all output performance
parameters.
Frequency/Voltage Conversion
The AMX Series is an excellent source of stable AC voltage over the frequency
range of 20 to 5,000 Hz. The output frequency is quartz-crystal stabilized.
Output voltages up to 600 VAC are provided.
Phase Conversion
With the ability to provide singe and three-phase outputs, the AMX Series is
the perfect choice to provide 1 Phase to 3 Phase or 3 Phase to 1 Phase
conversion.
Controller Selection Guide
Four controller models are available with the AMX-Series. They include 1 Phase
and 3 Phase models for both manual and programmable control.
-
UMC-31, 1/3 Phase Manual Control, 45 Hz to 500 Hz.
-
UPC-12, 1 Phase Programmable Control, 20 Hz to 5,000 Hz.
-
UPC-32, 3 Phase Programmable Control, 20 Hz to 5,000 Hz.
-
UPC-32E, 3 Phase Programmable Control, 20 Hz to 599.9 Hz.
All controllers provide manual operation from the front panel. Programmable
Controllers may be programmed from the front panel or from a remote interface.
IEEE 488 interface is standard. RS232 interface is optional.
Dual Range Output Magnetics Options
AMX Series Power Sources can be equipped with output transformers to provide an
alternate output voltage range. Selection of direct or transformer coupled
range is performed by the controller via front panel or bus command. The
standard frequency range for transformer coupled outputs is 45 to 5,000 Hz.
Standard output ratios are 1.5:1, 2.0:1, and 2.5:1. Transformer outputs are
supplied internally or externally via a Magnetics Module as listed in the above
table. Consult the factory for additional information regarding special output
ranges not listed above.
Power Source Specifications
Output Frequency:
20 to 5000 Hz. Full Power
Line Regulation:
0.1% max for a 10% line change
Load Regulation:
0.25% 20 to 2000 Hz. 0.5% 2000 to 5000 Hz. Can be improved to less than 0.03%
with CSC engaged.
Output Distortion:
0.1% THD from 20 to 1000 Hz 0.25% THD from 1000 to 5000 Hz
Ripple and Noise:
-72 dB
Response Time:
5µsec. typical to a step load change. Small signal band-width is 5 Hz. to 50
kHz, typical.
Mechanical Specifications
All models are designed for operation in 19 inch equipment racks. Models above
1800 VA have side handles for ease of handling.
Mounting:
Standard 19 inch rack. Slide rails are available as an option for all models.
Height:
See model table above for panel height.
Depth:
Will not exceed 24 inches from the front panel to the rear of the chassis,
including connectors, handles and cabling.
Cooling:
Forced air, front or side intakes, rear exhaust with auto fan speed control for
low acoustic noise operation.
UPC Controller Specifications
The UPC controller is essentially a single or three phase AC arbitrary waveform
generator and Precision AC metering system. The waveform for each phase may be
independently selected and may be independently varied in amplitude and phase
angle with respect to phase A (3 phase systems).
The UPC output metering samples the output volts and amps at 512 samples per
measurement using a 12 bit A/D converter. This technique provides exceptional
metering accuracy and resolution (20 bits), and delivers a high-fidelity
waveform back to a host computer for analysis.
The UPC includes a remote GPIB interface compatible with IEEE 488.2 and SCPI.
An available option is an RS-232 serial port that operates up to 38.4 kBaud.
Frequency:
20.00 to 5000 Hz ±0.01%
Voltage (Direct):
Programmable, 0-VMAX, in 0.1 volt steps (see table)
Phase Angle:
Phase Angle (f) of Phases B and C relative to Phase A is programmable from
0-359° in 1° increments ± 0.5°.
Current Limit:
Current limit is programmable from 0 to I peak maximum of the power source.
Accuracy is ± 1%, resolution ± 0.05%.
Waveform Library:
Stores up to 15 waveforms that can be edited and executed in any manner and in
any output phase.
Voltmeter:
Range: 0-354 volts L-N, 0-708 volts L-L
Resolution: 0.10VAC to front panel, 0.001VAC to remote interface
Accuracy: ± 0.25% of reading ± 0.1% of range (50-500Hz)
Ammeter:
Range: 300% of system current rating
Resolution: 0.01AAC to front panel, 0.001AAC to remote interface
Accuracy: ± 0.25% of reading ± 0.1% of range (50-500Hz)
Power Meter:
Range: Based on ammeter range
Resolution: 1.0 watts or VA to front panel, 0.001 Watts or VA to remote
interface
Accuracy: ± 1% of Full Scale
Power Factor & Crest Factor:
Calculated and displayed to three significant digits.
Expanding the AC Power Source into an Automated Test System
Pacific’s line of Smartsource® AC Power Sources enable the engineer to simply
automate his testing by using Lab VIEW for Windows® or LabWindows®. An
extensive list of Virtual Instruments (VIs) are offered for Pacific’s AMX
Series Power Sources.
Manual Control of AC Power

Provide easy manual control with Pacific’s UMC-31 Manual AC Power
Controller.
-
Obtain precision frequency and phase conversion for manufacturing and test
-
Provide high quality, general purpose lab power where test versatility is
required
-
Achieve low cost and power form flexibility for power supply tests.
The UMC-31 provides operational control and high quality oscillator signals for
both single and three phase Power Sources.
Specifications UMC-31 Controller
Phase:
Select single, split, or three phase operation by internal jumper. Phase angles
are fixed at 120° and 240° for three phase operation.
Frequency:
Select 50, 60, or 400 Hz fixed or a variable frequency mode of 45 to 500 Hz.
Voltage:
0-VMAX via 10 turn potentiometer on the front panel.
Metering:
Autoranging Volts, Amps, and Frequency.
Call for Technical and Application Assistance
Pacific’s technical people are here to assist you. As a technically oriented
company, we design, manufacture and service leading edge AC Test Power
equipment. We understand your requirement for strong applications support and
we provide it.
Product Brochure and Application Notes
To receive a PDF brochure and/or application notes for this product, please
contact us and check the boxes of the specific product(s) that you are
interested in or login in to the PPS Member area and download the files.
Specifications are subject to change without notice.
|