MS Series

Maximize Performance and Versatility and Virtually Eliminate Downtime

Solid State Frequency Converter with Models from 62.5 to 625 kVA,
Standard 47 to 500 Hz (optional to 1,000Hz)
 
Many custom solutions available. Contact us today!
 
Share  
 alt=
  • Maximize Performance and Versatility and Virtually Eliminate Downtime

    Pacific's unique master/slave configuration allows up to ten 62.5 kVA mainframes to be paralleled in the field. Any mainframe may be designated as the master. A failed unit is automatically disconnected from the power grid providing unmatched mission reliability.

    Pacific's MS-Series Power Source Systems Feature
    • Maximum system reliability
    • Rugged, powerful output
    • Lower installation cost
    • All frequency operation
    • Lower maintenance cost
    • Facility/test power flexibility
    • Unmatched performance/price ratio
    • Simple display and diagnostics
    • Uninterruptible Power Source configuration (UMS Option) readily available
  • True Advantages

    Solid State Technology with Unmatched Price/Performance Ratio
    Pacific MS-Series is a family of High Performance Line Conditioners/Frequency Converters that provides highly flexible, yet reliable, AC power ranging from 62.5 to 625 kVA. Using field-proven double conversion methods, the MS-Series offers unmatched power quality without sacrificing size or efficiency.

    Input AC power is rectified to DC by a special input power supply section. This minimizes input current distortion and prevents the load power factor from reflecting back onto the utility line. The DC is then converted back to AC by a high frequency, solid state, pulse-width modulated switchmode inverter under the control of a highly stable digital oscillator. The result is exceptional system performance with maximum reliability.

    Rugged, Powerful Output
    • 350 Amps of Pulse Current is delivered by each 3060-MS for driving non-linear loads.This eliminates the need to oversize power equirements as is common to rotary or low quality PWM power systems.
    • Load Power Factor is not an issue. The 3060-MS will drive virtually any load without damage or risk.
    • Excellent Regulation and response time eliminates load cross talk. Voltage sags common to other conversion methods are eliminated with 150 microsecond response time to a 50% load step. The output recovers to ± 3% of nominal within less than 1/10th of a cycle at 400 Hz.

    Maximum Reliability
    • Each 3060-MS is capable of operating as either the master or slave in a multi-cabinet parallel system. Calculated single cabinet MTBF is greater than five years.
    • Mission Reliability is assured. The parallel system architecture is such that a failed slave unit automatically removes itself from the power grid. Should the master unit fail, the operator can select any other paralleled unit as the new master from the front panel and restore system operation.

    Low Cost Ownership
    • Lower Maintenance Costs are achieved through built-in diagnostics that minimize MTTR. Quick and easy repair is facilitated with a small complement of local spares.
    • Input Power Factor is a constant 0.95 lagging, regardless of load. The MS Series actually corrects PF reflected back to the utility, eliminating PF penalties.
    • Low Installation Cost. The MS Series fits through standard doorways. Audible noise is limited to cooling fans. There is no 400 Hz whine that requires noise isolation. Solid state design with a forklift base eliminates the need for concrete pads and vibration isolators common to rotary installations.

    Facility/Test Power Flexibility
    • Power Levels Grow with demand. Units may be added or removed from the power grid as required.
    • Variable Frequency range of 47-500 Hz, as well as switch selectable fixed frequency operation of 50, 60 or 400 Hz is standard on every model (800Hz optional contact factory for more information).
    • External Input is provided as a standard feature. This allows operation as a variable frequency test power amplifier.
    • UPC-32 Programmable Controller Option is available to provide steady state and transient control of output power from the RS-232 or GPIB bus. Compatibility with UPC Studio graphical user interface.

    Simple/Informative Display
    • Measures volts, amps, watts and kVA for each input and output phase.
    • Efficiency is continuously monitored allowing system performance verification.
    • Internal Diagnostics assist in quickly locating failed components resulting in extremely low MTTR.
    • Power Generation circuits are separate from display and diagnostics. A failure in the display logic will not affect output power quality. Output power cannot be interrupted by system interrogation.
    • Audible and Visual Alarms alert the operator to any conditions requiring attention.

    Additional Features
    • Run time meter
    • Auto restart
    • RS-232 serial port for remote monitoring and diagnostics
    • Programmable voltage & frequency alarm set points
    • Local automatic gain control. Remote sense optional.
    • ETL Listing (optional on standard MS-Series cabinet only)
    • CE Mark (optional on standard MS-Series cabinet)
  • UMS Option

    MS Series Battery Support Systems
    The battery support system for a single cabinet UMS installation (62.5kVA, 50kW) consists of 30 sealed, maintenance free, immobilized electrolyte, batteries installed in an open battery rack. The UMS system DC voltage regulator provides for automatic charging of the battery system to maintain the proper float voltage.

    A battery disconnect center is located on the end of the battery rack.

    Battery support time at full load (50kW) is approximately 15 minutes. The waveform quality at the end of the battery support time meets the requirements of MIL-STD 1399, section 300A, Types I, II and III power forms.

    On-Line, No-Risk Battery Test
    This feature of the UMS system provides the ability to perform a battery test on command from the front panel or RS-232 serial port. Test results are displayed on the front panel and are available over the serial port as a part of the system diagnostics. A battery failure during the test will not cause the system to drop the load or distort the output waveform.
  • Electrical Specifications - Output

    Power:
    62.5kVA/50kW for each 3060-MS.

    Voltage:
    0-120/208, 3 phase. May be loaded either WYE or Delta. Other voltages are available as an option.

    Current:
    175 Arms per phase continuous. 350Apk per phase for non-linear loads.

    Load Transient Response and Recovery Time:
    150 microseconds for 50% load step and 300 microseconds for 100% load step.

    Load Power Factor:
    Any. Unit delivers full rated kVA into any power factor.

    Load Balance Restrictions:
    None. Each phase is independently regulated.

    Isolation:
    Input is fully isolated from output and frame ground.

    Protection:
    Integral electronic current limiting with auto recovery. Output CB optional.
     

    Electrical Specifications - Input

    Voltage:
    Universal input transformer with provisions for 208, 240, 380 and 480VAC, 3 phase + 10%.

    Frequency:
    47-63 Hz.
     

    Physical Specifications

    Size:
    36"W x 30"D x 72"H (see diagram).

    Weight:

    1600 lbs., Approximately 1700 lbs. shipping weight.

    Efficiency:
    85 to 90%.
     
  • MS Power Source

    MS Front


  • Product Brochure and Application Notes

     
    Download the Brochure
     
     
    Or review any of our other product brochures for download
     
     
     
     
  • Technical and Application Assistance

    Pacific Power Source's seasoned sales and service team is here to help via chat, email or a simple call. 
     
    You can also register to access our online applications documents.  

AMX SERIES

Amx Series Take Control of Your AC Power.
The AMX Series is a family of High Performance Linear AC power sources covering the power range from 500 VA to 12 kVA with standard models and up to 30 kVA with optional M5283 option. View This Series

ACX SERIES

The Model 118-ACX is the latest addition to the Pacific Power Sourceline of Manual and Programmable AC Power Sources. The 118-ACX is ideal for AC test, frequency conversion, laboratory and bench-power applications. View This Series

ASX SERIES

ASx Series Take Control of Your AC
Test Power.

Single and Three Phase AC Power Sources Models from 1 kVA to 12 kVA Manual or Programmable Control. View This Series

MS SERIES

Amx Series Maximize Performance and Versatility and Virtually Eliminate Downtime.
Solid State Frequency Converter with Models from 62.5 to 625 kVA, Standard 47 to 500 Hz (optional to 1,000Hz). View This Series